DIFERENCIAS DEL FLUJO PICO INSPIRATORIO A TRAVES DE TURBUHALER® Y DE ACCUHALER® UTILIZANDO EL DISPOSITIVO IN-CHECK® Y SU RELACION CON EL PICO MAXIMO INSPIRATORIO

(especial para SIIC © Derechos reservados)

Las diferencias entre los dispositivos de inhalación de polvo seco se centran en la manejabilidad, facilidad para aprender su uso y principalmente la capacidad por parte del enfermo para extraer el fármaco y depositarlo en el pulmón en las mejores condiciones.
Profesor Luis García-Marcos Alvarez Autor:
Luis García-Marcos Alvarez
Columnista Experto de SIIC

Institucion:
Universidad de Murcia y Unidad de Investigación Clínico-Epidemiológica, Dirección de Salud del Area II, Cartagena, Murcia, España

Artículos publicados por Luis García-Marcos Alvarez 
participaron en la investigación
Antonia Martínez Torres (Enfermera)* Dr. José Jesús Guillén Pérez*
*Unidad de Investigación Clínico-Epidemiológica, Dirección de Salud del Area II, Cartagena

Recepción del artículo: 31 de Octubre, 2002

Aprobación: 10 de Enero, 2003

Primera edición: 14 de Enero, 2003

Segunda edición, ampliada y corregida 24 de Noviembre, 2003
Resumen
Antecedentes: la medicación inhalatoria a través de dispositivos de polvo seco se utiliza cada vez más, pero hay pocos estudios que determinen a qué edades es posible su uso. Objetivos: establecer la diferencia en el pico de flujo inspiratorio (PIF) a través de Accuhaler® y Turbuhaler® en niños normales por medio del dispositivo In-check® y determinar las diferencias entre dos modelos distintos de este aparato. Averiguar la relación de éstos con el pico de flujo inspiratorio (PIF) medido mediante un neumotacógrafo. Métodos: a 64 niños normales (media 11.2 años) se les midió el PIF con un espirómetro Datospir-100, así como con In-check® e In-check Dial® utilizando las resistencias de Accuhaler® y Turbuhaler®. Se eligió la mejor maniobra de entre tres. Además se midió peso, talla y FEV1. Resultados: hubo diferencias significativas cuando se compararon las resistencias de ambos inhaladores: PIF In-checkAccuhaler-PIF In-checkTurbuhaler (134.4 ± 15.5 vs. 99.9 ± 11.1; p < 0.000) y PIF In-check DialAccuhaler-PIF In-check DialTurbuhaler (109.6 ± 10.5 vs. 86.8 ± 8.9; p < 0.000). Las correl aciones (controladas para edad y talla) entre el PIF y los diferentes PIF-In-check fueron mejores para el In-checkAccuhaler. Conclusiones: El PIF a través de Accuhaler® es significativamente mayor que a través de Turbuhaler®. Existe una mayor correlación entre el PIF sin resistencia medido por espirometría y el In- checkAccuhaler que entre ese parámetro espirométrico y el In-checkTurbuhaler.

Palabras clave
Flujo pico inspiratorio, inhalador de polvo seco, In-check, Accuhaler, Turbuhaler, asma, niño.

Clasificación en siicsalud
Artículos originales> Expertos de Iberoamérica>
página www.siicsalud.com/des/des031/03113001.htm

Especialidades
Principal: Pediatría
Relacionadas: Neumonología

Enviar correspondencia a:
Profesor Luis García-Marcos Alvarez, Unidad de Investigación Clínico-Epidemiológica. Pza. San Agustín, 3. 30201 Cartagena, España

Artículo completo
(castellano)
Extensión:  +/- 6.97 páginas impresas en papel A4
Exclusivo para suscriptores/ assinantes

DIFFERENCES BETWEEN PEAK INSPIRATORY FLOW TROUGH ACCUHALER AND TURBUHALER USING AN IN-CHECK DEVICE AND THEIR RELATIONSHIPS WITH PIF WITHOUT RESISTANCE

Abstract
Background: Inhaled medication through dry powder inhalers is widely used in children, but pediatric studies that focus on the ages that those devices can be used, are sparse. Objective: To establish the difference of peak inspiratory flow (PIF) through AccuhalerTM and TurbuhalerTM in normal children using the new device In-checkTM; and to find out the differences of two models of this device; and to know the relationship of those with PIF without resistance measured usig a pneumotacograph. Methods: PIF was measured in 64 male normal children (mean age 11,2 years, range 8,8-14,7) by means of In-checkTM and In- check DialTM using the AccuhalerTM and TurbuhalerTM resistances. The best attempt of three was chosen. Also, weight, height and FEV1 were measured. Results: There were significant differences in PIF between the two inhalers: PIF In-checkAccuhaler-PIF In-checkTurbuhaler (134.4 ± 15.5 l/min vs 99.9 ± 11.1 l/min; p < 0.000) and PIF In-check DialAccuhaler- PIF In-check DialTurbuhaler (109.6 ± 10.5 l/min vs. 86.8 ± 8.9 l/min; p < 0.000). Controlled (for age and height) correlations between PIF without resistance and the In-checkTM devices were best for In-checkAccuhaler. Conclusions: PIF through AccuhalerTM is significantly higher than through TurbuhalerTM. There is a better correlation between PIF without resistance and In-checkAccuhaler than berween non-resistant PIF and In- checkTurbuhaler.


Key words
Inspiratory peak flow, dry powder inhaled, In-check, Accuhaler, Turbuhaler, asthma, children.

Bibliografía del artículo

  1. Fuller R. The Diskus: A new multi dose powder device, Efficacy and comparison with Turbuhaler. J Aerosol Med 1995; 8: S11I-S17.
  2. Malton A, Sumby BS, Smith IJ. A comparison of in vitro drug delivery from two multidose powder inhalation devices. Eur J Clin Res 1995; 7: 177-93.
  3. Malton A, Sumby BS, Dandiker Y. A comparison of in-vitro drug delivery from salbutamol Diskus and terbutaline Turbohaler inhalers. J Pharm Med 1996; 6: 35-48.
  4. Bisgaard H, Klug B, Sumby BS, Bumell PKP. Fine particle mass from the Diskus inhaler and Turbuhaler inhaler in children with asthma. Eur Respir J l998; 11: 1111-15.
  5. Prime D, Grant AC, Slater AL, Woodhouse RN. A critical comparison of the dose delivery characteristics of four alternative inhalation devices delivering salbutamol: pressurized metered dose inhaler, diskus inhaler, diskhaler inhaler, and turbuhaler inhaler. J Aerosol Med 1999; 12: 75-84.
  6. Schlaeppi M, Edwards K, Fuller RW, Shanna R. Patient perception of the diskus inhaler: a comparison with the turbuhaler inhaler. Br J Clin Pract 1996; 50: 14-19.
  7. Shanna RK, Edwards K, Hallett C, Fuller RW. Perception among paediatric patients of the diskus inhaler, a novel multidose powder inhaler for use in the treatment of asthma. Comparison with the turbuhaler inhaler. Clin Drug Invest 1996; 11: 145-53.
  8. Meakin BJ, Cainey JM, Woodcock PM. Drug delivery characteristics of Bricanyl Turbuhaler dry powder inhaler. Int J Pharmaceuticals 1995; 119: 91-102
  9. Aguilar P, Mallol J. Flujos inspiratorios máximos en niños sanos y asmáticos de 4 a 8 años. Implicaciones para la inhalación de medicamentos en polvo. Arch Bronconeumol 2000; 2: 73-76
Título español/
Resumen
 Palabras clave
 Bibliografía
 Artículo completo
(exclusivo suscriptores)
 Autoevaluación
 Tema principal en SIIC Data Base
 Especialidades

 English title
 Abstract

 Key words

Autor 
Artículos
Correspondencia

Patrocinio

Imprimir esta página

 

Clasificado en 
Artículos originales>
Expertos de Iberoamérica

Especialidad principal:
Pediatría
 
Relacionadas: 
 Neumonología

 

Suscripción a siicsalud

Comprar este artículo
Extensión: ± 6.97 páginas impresas en papel A4

file05.gif (1491 bytes) Artículos seleccionados para su compra

 


© Está expresamente prohibida la redistribución y la redifusión de todo o parte de los contenidos de la Sociedad Iberoamericana de Información Científica (SIIC) S.A. sin previo y expreso consentimiento de SIIC.

anterior.gif (1015 bytes)



Suscripción a siicsalud

Bienvenidos a siicsalud

Acerca de SIIC Estructura de SIIC
Círculo de Lectores SIIC Salud(i)Ciencia Trabajos Distinguidos


Sociedad Iberoamericana de Información Científica (SIIC)
Av. Belgrano 430, (C1092AAR), Buenos Aires, Argentina
Correo electrónico (e-mail): atencionallector@siicsalud.com;  Tels: 0054 11 4342-4901; Fax: 0054 11 4331-3305.
Correo SIIC: Casilla de Correo 2568, (C1000WAZ) Correo Central, Buenos Aires.
Copyright siicsalud© 1997-2003, Sociedad Iberoamericana de Información Científica(SIIC)