Suresh Rana describes for SIIC the most significant aspects of his article describe para SIIC los aspectos relevantes de su artículo Tissue heterogeneity corrections within photon dose calculation algorithms DOSE PREDICTION ACCURACY OF ECLIPSE PHOTON DOSE CALCULATION ALGORITHMS Acuros® XB is more accurate than pencil beam convolution (PBC) and anisotropic analytical algorithm (AAA) for photon dose calculations when tissue heterogeneities are involved along the photon beam path. The article was published by El artículo fue publicado por
Principal institution where the research took place Institución principal de la investigación Arizona Center for Cancer Care, Peoria, Arizona, United States Authors' Report Crónica del Autor Bibliographic references Referencias bibliográficas Rana SB. Dose prediction accuracy of anisotropic analytical algorithm and pencil beam convolution algorithm beyond high density heterogeneity interface. South Asian J Cancer 2:26-30, 2013. Rana S, Rogers K. Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes. J Med Phys 38:9-14, 2013. Other articles written by the author Suresh Rana Otros artículos de Suresh Rana 1.Rana S, Rogers K. Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes. Journal of Medical Physics 2013; 38:9-14. 2.Rana SB, Rogers K, Lee T, Reed D, Biggs C. Verification and Dosimetric Impact of Acuros XB Algorithm for Stereotactic Body Radiation Therapy (SBRT) and RapidArc Planning for Non-Small-Cell Lung Cancer (NSCLC) Patients. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology 2013; 2:6-14. 3.Rana SB, Rogers K, Pokharel S. Acuros XB Algorithm vs. Anisotropic Analytical Algorithm: A Dosimetric Study using Heterogeneous Phantom and Computed Tomography (CT) Data Sets of Esophageal Cancer Patients. Journal of Cancer Therapy 2013; 4:138-144 SIIC System of Assisted Editing (SSEA) / Sistema SIIC de Edición Asistida (SSEA)
The article is strictly related to the following sections of siicsalud El artículo se relaciona estrictamente con las siguientes secciones de siicsalud
Information about the full text Acerca del trabajo completo Dose Prediction Accuracy of Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm Beyond High Density Heterogeneity Interface Author / Autor Suresh Rana1 1 Mr., (1) Procure Proton Therapy Center, Oklahoma City, Ok (2) Arizona Center For Cancer Care, Peoria, Az, Oklahoma City, EE.UU., Medical Physicist Access to the original source South Asian Journal of Cancer Article URL: / URL del artículo: URL of Abstract: / URL del abstract: http://journal.sajc.org/article.asp?issn=2278-330X;year=2013;volume=2;issue=1;spage=26;epage=30;aulast=Rana;type=0 siic DB: / siic DB: http://www.siicsalud.com/main/distriprinrel.php |
Copyright siicsalud © 1997-2024 ISSN siicsalud: 1667-9008